Fiber Optics GHCP4002 Specification Sheet
 
		SKU: GHCP4002
		
		
	  
	  Price:
		
	    
		
		
		
		
			
				
					
		
		
		
	  
	  $756.00
		
		| Quantity: | 3+ | 9+ | 20+ | 40+ | 100+ | 
| Price: | $726.00 | $706.50 | $679.50 | $657.00 | $603.00 | 
Applications: General purpose duplex cable for industrial data applications, UL VW-1 1581 Style No. 5310 rated
Spool Length: 500 m
Pricing (per meter) $3.35
Stock No: 81 0124
| Structure | ||||||
| Core Material | Polymethyl-Methacrylate Resin | |||||
| Cladding Material | Fluorinated Polymer | |||||
| Core Refractive Index | 1.49 | |||||
| Refractive Index Profile | Step-index | |||||
| Numerical Aperture | .50 | |||||
| Number of Fibers | 2 | |||||
| Unit | Value | |||||
| Core Diameter | µm | 920 - 1040 | ||||
| Cladding Diameter | µm | 940 - 1060 | ||||
| Approximate Weight | g/m | 11.1 | ||||
| Jacket | ||||||
| Material and Color | Chlorinated Polyethylene (Black) | |||||
| Indication on Jacket | Blue; E89328 Mitsubishi Rayon AWM 5310 80C VW-1(One of the Pair) | |||||
| Unit | Value | |||||
| Sub-unit Diameter | mm | 0 | ||||
| Outer Diameter | mm | 2.2 x 4.4 ± .1 | ||||
| Fiber Tensile Strength | N | 140 | ||||
| Performance | Criteria for Acceptance and/or [ Test Conditions ]  | 
            Unit | Value | |||||
| Maximum Rating  | 
            Storage Temperature | No Physical Deterioration [ in a Dry Atmosphere ]  | 
            ° C | - 55 ~ 85 | ||||
| Operation Temperature | No Deterioration in Optical Properties [ in a Dry Atmosphere ]  | 
            ° C | - 55 ~ 85 | |||||
| No Deterioration in Optical Properties [ under 95% RH condition ]  | 
            ° C | - 55 ~ 85 | ||||||
| Optical Properties  | 
            Transmission Loss | (650 nm Collimated Light) [ 25°C 50% RH ]  | 
            dB/m | .17 Max. | ||||
| Transmission Loss under 95% RH  | 
            (650 nm Collimated Light) [ Operation Temperature ]  | 
            dB/m | .19 Max. | |||||
| Mechanical Characteristics  | 
            Minimum Bend Radius | Loss Increment <0.5 dB [ A Quarter Bend ]***  | 
            mm | 25 | ||||
| Repeated Bending Endurance  | 
            Loss Increment <1 dB [ In conformity to the JIS C 6861 ]***  | 
            Times | 10,000 | |||||
| Tensile Strength | Tensile Force at 5% [ Elongation; in Conformity to the JIS C 6861 ]  | 
            N | 140 | |||||
| Twisting Strength | Loss Increment <1 dB [ Sample Length: 1 m Tensile Force: 4.9 N ]  | 
            Times | 2 | |||||
| Impact Strength | Loss Increment <1 dB [ Sample Length: 1 m JIS C 6861 ]  | 
            N.m | 0.4 | |||||