Manufactured: OFS
Manufacturer's PDF Data Sheet
Applications: Outdoor Industrial
Spool Length: n/a
Price (per meter)
| Structure | ||||||
| Core Material | silica | |||||
| Cladding Material | polymer | |||||
| Core Refractive Index | 1.452 @ 850 nm | |||||
| Refractive Index Profile | Step-index | |||||
| Numerical Aperture | .37 | |||||
| Number of Fibers | 2 | |||||
| Unit | Value | |||||
| Core Diameter | µm | 200 ± 4 | ||||
| Cladding Diameter | µm | 230 | ||||
| Approximate Weight | g/m | 45 | ||||
| Jacket | ||||||
| Material and Color | ?/PE/ Black | |||||
| Indication on Jacket | ||||||
| Unit | Value | |||||
| Sub-unit Diameter | mm | 2.5 ± 0.2 | ||||
| Outer Diameter | mm | 8 | ||||
| Fiber Tensile Strength | N | 689 | ||||
| Performance | Criteria for Acceptance and/or [ Test Conditions ]  | 
            Unit | Value | |||||
| Maximum Rating  | 
            Storage Temperature | No Physical Deterioration [ in a Dry Atmosphere ]  | 
            ° C | -40 to +80 | ||||
| Operation Temperature | No Deterioration in Optical Properties [ in a Dry Atmosphere ]  | 
            ° C | -40 to +80 | |||||
| No Deterioration in Optical Properties [ under 95% RH condition ]  | 
            ° C | -40 to +80 | ||||||
| Optical Properties  | 
            Transmission Loss | (650 nm Collimated Light) [ 25°C 50% RH ]  | 
            dB/m | < 6 dB/km @ 850 nm | ||||
| Transmission Loss under 95% RH  | 
            (650 nm Collimated Light) [ Operation Temperature ]  | 
            dB/m | ||||||
| Mechanical Characteristics  | 
            Minimum Bend Radius | Loss Increment <0.5 dB [ A Quarter Bend ]***  | 
            mm | 120 | ||||
| Repeated Bending Endurance  | 
            Loss Increment <1 dB [ In conformity to the JIS C 6861 ]***  | 
            Times | ||||||
| Tensile Strength | Tensile Force at 5% [ Elongation; in Conformity to the JIS C 6861 ]  | 
            N | 689 | |||||
| Twisting Strength | Loss Increment <1 dB [ Sample Length: 1 m Tensile Force: 4.9 N ]  | 
            Times | ||||||
| Impact Strength | Loss Increment <1 dB [ Sample Length: 1 m JIS C 6861 ]  | 
            N.m | ||||||